Guide d'implémentation Fr Core
2.0.0-ballot - trial-use
This page is part of the Guide d'implémentation Fr Core (v2.0.0-ballot: Release) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions
Official URL: https://hl7.fr/ig/fhir/core/StructureDefinition/fr-core-observation-bp | Version: 2.0.0-ballot | |||
Draft as of 2024-02-20 | Computable Name: FRCoreObservationBpProfile |
French profil Blood pressure panel with all children optional - This is a component observation. It has no value in Observation.valueQuantity and contains at least one component (systolic and/or diastolic and/or mean) | Profil français de pression artérielle avec tous les éléments fils optionnels. Il s’agit d’une Observation avec l’élément Observation.valueQuantity n’est pas renseigné et qui contient au moins un composant Pression systolique, Pression diastolique, Pression moyenne. |
Usage:
Description of Profiles, Differentials, Snapshots and how the different presentations work.
This structure is derived from observation-bp
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | 0..* | observation-bp | FHIR Blood Pressure Profile | |
meta | ||||
Slices for profile | 0..* | canonical(StructureDefinition) | Profiles this resource claims to conform to Slice: Unordered, Open by value:$this | |
profile:fr-canonical | 0..1 | canonical(StructureDefinition) | Profiles this resource claims to conform to Required Pattern: https://hl7.fr/ig/fhir/core/StructureDefinition/fr-core-observation-bp | |
Slices for extension | 0..* | Extension | Extension Slice: Unordered, Open by value:url | |
supportingInfo | 0..1 | Reference(Resource) | Other information that may be relevant to this event. URL: http://hl7.org/fhir/StructureDefinition/workflow-supportingInfo | |
code | ||||
coding | 1..* | Coding | Code defined by a terminology system | |
encounter | 0..1 | Reference(FR Core Encounter Profile) | Healthcare event during which this observation is made | |
effective[x] | 1..1 | dateTime, Period | Often just a dateTime for Vital Signs | |
performer | 0..* | Reference(CareTeam | FR Core Patient Profile | FR Core Practitioner Profile | PractitionerRole | FR Core Organization Profile | FR Core Related Person Profile) | Who is responsible for the observation | |
value[x] | 0..0 | |||
bodySite | 0..1 | CodeableConcept | Observed body part Binding: http://hl7.org/fhir/hspc/ValueSet/bpMeasBodyLocationPrecoordVS (example) | |
method | 0..1 | CodeableConcept | How it was done Binding: https://hl7.fr/ig/fhir/core/ValueSet/fr-core-vs-bp-measurement-method (example) | |
component:SystolicBP | 1..1 | BackboneElement | Used when reporting systolic and diastolic blood pressure. | |
code | ||||
coding | 1..* | Coding | Systolic Blood Pressure | |
value[x] | 0..1 | Quantity | Vital Sign Value recorded with UCUM Slice: Unordered, Open by | |
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |
component:DiastolicBP | 1..1 | BackboneElement | Used when reporting diastolic blood pressure. | |
code | ||||
coding | 1..* | Coding | Diastolic Blood Pressure | |
value[x] | 0..1 | Quantity | Vital Sign Value recorded with UCUM Slice: Unordered, Open by | |
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |
component:MeanBP | 0..1 | BackboneElement | Mean blood pressure | |
code | ||||
Slices for coding | 1..* | Coding | Code defined by a terminology system Slice: Unordered, Open by value:code, value:system | |
coding:MBPCode | 1..1 | Coding | Code defined by a terminology system | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Mean blood pressure Fixed Value: 8478-0 | |
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |
Documentation for this format |
Path | Conformance | ValueSet | URI |
Observation.bodySite | example | http://hl7.org/fhir/hspc/ValueSet/bpMeasBodyLocationPrecoordVShttp://hl7.org/fhir/hspc/ValueSet/bpMeasBodyLocationPrecoordVS | |
Observation.method | example | https://hl7.fr/ig/fhir/core/ValueSet/fr-core-vs-bp-measurement-methodhttps://hl7.fr/ig/fhir/core/ValueSet/fr-core-vs-bp-measurement-method |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | C | 0..* | observation-bp | FHIR Blood Pressure Profile |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
Slices for extension | 0..* | Extension | Extension Slice: Unordered, Open by value:url | |
supportingInfo | 0..1 | Reference(Resource) | Other information that may be relevant to this event. URL: http://hl7.org/fhir/StructureDefinition/workflow-supportingInfo | |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
status | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: ObservationStatus (required) |
Slices for category | S | 1..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by value:coding.code, value:coding.system Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. |
category:VSCat | S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. |
coding | SΣ | 1..* | Coding | Code defined by a terminology system |
system | SΣ | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category |
code | SΣ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: vital-signs |
code | SΣ | 1..1 | CodeableConcept | Blood Pressure Binding: VitalSigns (extensible): This identifies the vital sign result type. |
Slices for coding | Σ | 1..* | Coding | Code defined by a terminology system Slice: Unordered, Open by value:code, value:system |
coding:BPCode | Σ | 1..1 | Coding | Code defined by a terminology system |
system | Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org |
code | Σ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 85354-9 |
subject | SΣ | 1..1 | Reference(Patient) | Who and/or what the observation is about |
encounter | Σ | 0..1 | Reference(FR Core Encounter Profile) | Healthcare event during which this observation is made |
effective[x] | SΣC | 1..1 | Often just a dateTime for Vital Signs | |
effectiveDateTime | dateTime | |||
effectivePeriod | Period | |||
performer | Σ | 0..* | Reference(CareTeam | FR Core Patient Profile | FR Core Practitioner Profile | PractitionerRole | FR Core Organization Profile | FR Core Related Person Profile) | Who is responsible for the observation |
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
bodySite | 0..1 | CodeableConcept | Observed body part Binding: http://hl7.org/fhir/hspc/ValueSet/bpMeasBodyLocationPrecoordVS (example) | |
method | 0..1 | CodeableConcept | How it was done Binding: https://hl7.fr/ig/fhir/core/ValueSet/fr-core-vs-bp-measurement-method (example) | |
Slices for component | SΣC | 2..* | BackboneElement | Used when reporting systolic and diastolic blood pressure. Slice: Unordered, Open by value:code.coding.code, value:code.coding.system |
component:All Slices | Content/Rules for all slices | |||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: VitalSigns (extensible): This identifies the vital sign result type. |
value[x] | SΣC | 0..1 | Vital Sign Value recorded with UCUM Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. | |
valueQuantity | Quantity | |||
valueCodeableConcept | CodeableConcept | |||
valueString | string | |||
valueBoolean | boolean | |||
valueInteger | integer | |||
valueRange | Range | |||
valueRatio | Ratio | |||
valueSampledData | SampledData | |||
valueTime | time | |||
valueDateTime | dateTime | |||
valuePeriod | Period | |||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
component:SystolicBP | SΣC | 1..1 | BackboneElement | Used when reporting systolic and diastolic blood pressure. |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: VitalSigns (extensible): This identifies the vital sign result type. |
Slices for coding | Σ | 1..* | Coding | Systolic Blood Pressure Slice: Unordered, Open by value:code, value:system |
coding:SBPCode | Σ | 1..1 | Coding | Systolic Blood Pressure |
system | Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org |
code | Σ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 8480-6 |
value[x] | SΣC | 0..1 | Quantity | Vital Sign Value recorded with UCUM Slice: Unordered, Open by type:$this Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. |
value[x]:All Slices | Content/Rules for all slices | |||
value | SΣ | 1..1 | decimal | Numerical value (with implicit precision) |
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. |
unit | SΣ | 1..1 | string | Unit representation |
system | SΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
code | SΣ | 1..1 | code | Coded responses from the common UCUM units for vital signs value set. Fixed Value: mm[Hg] |
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |
component:DiastolicBP | SΣC | 1..1 | BackboneElement | Used when reporting diastolic blood pressure. |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: VitalSigns (extensible): This identifies the vital sign result type. |
Slices for coding | Σ | 1..* | Coding | Diastolic Blood Pressure Slice: Unordered, Open by value:code, value:system |
coding:DBPCode | Σ | 1..1 | Coding | Diastolic Blood Pressure |
system | Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org |
code | Σ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 8462-4 |
value[x] | SΣC | 0..1 | Quantity | Vital Sign Value recorded with UCUM Slice: Unordered, Open by type:$this Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. |
value[x]:All Slices | Content/Rules for all slices | |||
value | SΣ | 1..1 | decimal | Numerical value (with implicit precision) |
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. |
unit | SΣ | 1..1 | string | Unit representation |
system | SΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
code | SΣ | 1..1 | code | Coded responses from the common UCUM units for vital signs value set. Fixed Value: mm[Hg] |
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |
component:MeanBP | SΣC | 0..1 | BackboneElement | Mean blood pressure |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: VitalSigns (extensible): This identifies the vital sign result type. |
Slices for coding | Σ | 1..* | Coding | Code defined by a terminology system Slice: Unordered, Open by value:code, value:system |
coding:MBPCode | Σ | 1..1 | Coding | Code defined by a terminology system |
system | Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org |
code | Σ | 1..1 | code | Mean blood pressure Fixed Value: 8478-0 |
value[x] | SΣC | 0..1 | Vital Sign Value recorded with UCUM Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. | |
valueQuantity | Quantity | |||
valueCodeableConcept | CodeableConcept | |||
valueString | string | |||
valueBoolean | boolean | |||
valueInteger | integer | |||
valueRange | Range | |||
valueRatio | Ratio | |||
valueSampledData | SampledData | |||
valueTime | time | |||
valueDateTime | dateTime | |||
valuePeriod | Period | |||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |
Documentation for this format |
Path | Conformance | ValueSet | URI |
Observation.status | required | ObservationStatushttp://hl7.org/fhir/ValueSet/observation-status|4.0.1 from the FHIR Standard | |
Observation.category | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | |
Observation.category:VSCat | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | |
Observation.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresult from the FHIR Standard | |
Observation.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
Observation.bodySite | example | http://hl7.org/fhir/hspc/ValueSet/bpMeasBodyLocationPrecoordVShttp://hl7.org/fhir/hspc/ValueSet/bpMeasBodyLocationPrecoordVS | |
Observation.method | example | https://hl7.fr/ig/fhir/core/ValueSet/fr-core-vs-bp-measurement-methodhttps://hl7.fr/ig/fhir/core/ValueSet/fr-core-vs-bp-measurement-method | |
Observation.component.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresult from the FHIR Standard | |
Observation.component.value[x] | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1 from the FHIR Standard | |
Observation.component.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
Observation.component:SystolicBP.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresult from the FHIR Standard | |
Observation.component:SystolicBP.value[x] | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1 from the FHIR Standard | |
Observation.component:SystolicBP.value[x].comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1 from the FHIR Standard | |
Observation.component:SystolicBP.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
Observation.component:DiastolicBP.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresult from the FHIR Standard | |
Observation.component:DiastolicBP.value[x] | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1 from the FHIR Standard | |
Observation.component:DiastolicBP.value[x].comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1 from the FHIR Standard | |
Observation.component:DiastolicBP.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
Observation.component:MeanBP.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresult from the FHIR Standard | |
Observation.component:MeanBP.value[x] | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1 from the FHIR Standard | |
Observation.component:MeanBP.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | Observation | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | Observation | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | Observation | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() | |
obs-6 | error | Observation | dataAbsentReason SHALL only be present if Observation.value[x] is not present : dataAbsentReason.empty() or value.empty() | |
obs-7 | error | Observation | If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present : value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty() | |
vs-1 | error | Observation.effective[x] | if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day : $this is dateTime implies $this.toString().length() >= 10 | |
vs-2 | error | Observation | If there is no component or hasMember element then either a value[x] or a data absent reason must be present. : (component.empty() and hasMember.empty()) implies (dataAbsentReason.exists() or value.exists()) | |
vs-3 | error | Observation.component, Observation.component:SystolicBP, Observation.component:DiastolicBP, Observation.component:MeanBP | If there is no a value a data absent reason must be present : value.exists() or dataAbsentReason.exists() |
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
Observation | C | 0..* | observation-bp | FHIR Blood Pressure Profile | ||||
id | Σ | 0..1 | id | Logical id of this artifact | ||||
meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
versionId | Σ | 0..1 | id | Version specific identifier | ||||
lastUpdated | Σ | 0..1 | instant | When the resource version last changed | ||||
source | Σ | 0..1 | uri | Identifies where the resource comes from | ||||
Slices for profile | Σ | 0..* | canonical(StructureDefinition) | Profiles this resource claims to conform to Slice: Unordered, Open by value:$this | ||||
profile:fr-canonical | Σ | 0..1 | canonical(StructureDefinition) | Profiles this resource claims to conform to Required Pattern: https://hl7.fr/ig/fhir/core/StructureDefinition/fr-core-observation-bp | ||||
security | Σ | 0..* | Coding | Security Labels applied to this resource Binding: All Security Labels (extensible): Security Labels from the Healthcare Privacy and Security Classification System. | ||||
tag | Σ | 0..* | Coding | Tags applied to this resource Binding: CommonTags (example): Codes that represent various types of tags, commonly workflow-related; e.g. "Needs review by Dr. Jones". | ||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
contained | 0..* | Resource | Contained, inline Resources | |||||
Slices for extension | 0..* | Extension | Extension Slice: Unordered, Open by value:url | |||||
supportingInfo | 0..1 | Reference(Resource) | Other information that may be relevant to this event. URL: http://hl7.org/fhir/StructureDefinition/workflow-supportingInfo | |||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
identifier | Σ | 0..* | Identifier | Business Identifier for observation | ||||
basedOn | Σ | 0..* | Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) | Fulfills plan, proposal or order | ||||
partOf | Σ | 0..* | Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) | Part of referenced event | ||||
status | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: ObservationStatus (required) | ||||
Slices for category | S | 1..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by value:coding.code, value:coding.system Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. | ||||
category:VSCat | S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
coding | SΣ | 1..* | Coding | Code defined by a terminology system | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
system | SΣ | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | ||||
version | Σ | 0..1 | string | Version of the system - if relevant | ||||
code | SΣ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: vital-signs | ||||
display | Σ | 0..1 | string | Representation defined by the system | ||||
userSelected | Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
text | Σ | 0..1 | string | Plain text representation of the concept | ||||
code | SΣ | 1..1 | CodeableConcept | Blood Pressure Binding: VitalSigns (extensible): This identifies the vital sign result type. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
Slices for coding | Σ | 1..* | Coding | Code defined by a terminology system Slice: Unordered, Open by value:code, value:system | ||||
coding:BPCode | Σ | 1..1 | Coding | Code defined by a terminology system | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
system | Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | ||||
version | Σ | 0..1 | string | Version of the system - if relevant | ||||
code | Σ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 85354-9 | ||||
display | Σ | 0..1 | string | Representation defined by the system | ||||
userSelected | Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
text | Σ | 0..1 | string | Plain text representation of the concept | ||||
subject | SΣ | 1..1 | Reference(Patient) | Who and/or what the observation is about | ||||
focus | Σ | 0..* | Reference(Resource) | What the observation is about, when it is not about the subject of record | ||||
encounter | Σ | 0..1 | Reference(FR Core Encounter Profile) | Healthcare event during which this observation is made | ||||
effective[x] | SΣC | 1..1 | Often just a dateTime for Vital Signs | |||||
effectiveDateTime | dateTime | |||||||
effectivePeriod | Period | |||||||
issued | Σ | 0..1 | instant | Date/Time this version was made available | ||||
performer | Σ | 0..* | Reference(CareTeam | FR Core Patient Profile | FR Core Practitioner Profile | PractitionerRole | FR Core Organization Profile | FR Core Related Person Profile) | Who is responsible for the observation | ||||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
note | 0..* | Annotation | Comments about the observation | |||||
bodySite | 0..1 | CodeableConcept | Observed body part Binding: http://hl7.org/fhir/hspc/ValueSet/bpMeasBodyLocationPrecoordVS (example) | |||||
method | 0..1 | CodeableConcept | How it was done Binding: https://hl7.fr/ig/fhir/core/ValueSet/fr-core-vs-bp-measurement-method (example) | |||||
specimen | 0..1 | Reference(Specimen) | Specimen used for this observation | |||||
device | 0..1 | Reference(Device | DeviceMetric) | (Measurement) Device | |||||
referenceRange | C | 0..* | BackboneElement | Provides guide for interpretation | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
low | C | 0..1 | SimpleQuantity | Low Range, if relevant | ||||
high | C | 0..1 | SimpleQuantity | High Range, if relevant | ||||
type | 0..1 | CodeableConcept | Reference range qualifier Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range. | |||||
appliesTo | 0..* | CodeableConcept | Reference range population Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to. | |||||
age | 0..1 | Range | Applicable age range, if relevant | |||||
text | 0..1 | string | Text based reference range in an observation | |||||
hasMember | Σ | 0..* | Reference(QuestionnaireResponse | MolecularSequence | Vital Signs Profile) | Used when reporting vital signs panel components | ||||
derivedFrom | Σ | 0..* | Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | MolecularSequence | Vital Signs Profile) | Related measurements the observation is made from | ||||
Slices for component | SΣC | 2..* | BackboneElement | Used when reporting systolic and diastolic blood pressure. Slice: Unordered, Open by value:code.coding.code, value:code.coding.system | ||||
component:All Slices | Content/Rules for all slices | |||||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: VitalSigns (extensible): This identifies the vital sign result type. | ||||
value[x] | SΣC | 0..1 | Vital Sign Value recorded with UCUM Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. | |||||
valueQuantity | Quantity | |||||||
valueCodeableConcept | CodeableConcept | |||||||
valueString | string | |||||||
valueBoolean | boolean | |||||||
valueInteger | integer | |||||||
valueRange | Range | |||||||
valueRatio | Ratio | |||||||
valueSampledData | SampledData | |||||||
valueTime | time | |||||||
valueDateTime | dateTime | |||||||
valuePeriod | Period | |||||||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
component:SystolicBP | SΣC | 1..1 | BackboneElement | Used when reporting systolic and diastolic blood pressure. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: VitalSigns (extensible): This identifies the vital sign result type. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
Slices for coding | Σ | 1..* | Coding | Systolic Blood Pressure Slice: Unordered, Open by value:code, value:system | ||||
coding:SBPCode | Σ | 1..1 | Coding | Systolic Blood Pressure | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
system | Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | ||||
version | Σ | 0..1 | string | Version of the system - if relevant | ||||
code | Σ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 8480-6 | ||||
display | Σ | 0..1 | string | Representation defined by the system | ||||
userSelected | Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
text | Σ | 0..1 | string | Plain text representation of the concept | ||||
value[x] | SΣC | 0..1 | Quantity | Vital Sign Value recorded with UCUM Slice: Unordered, Open by type:$this Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. | ||||
value[x]:All Slices | Content/Rules for all slices | |||||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
value | SΣ | 1..1 | decimal | Numerical value (with implicit precision) | ||||
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. | ||||
unit | SΣ | 1..1 | string | Unit representation | ||||
system | SΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org | ||||
code | SΣ | 1..1 | code | Coded responses from the common UCUM units for vital signs value set. Fixed Value: mm[Hg] | ||||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
component:DiastolicBP | SΣC | 1..1 | BackboneElement | Used when reporting diastolic blood pressure. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: VitalSigns (extensible): This identifies the vital sign result type. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
Slices for coding | Σ | 1..* | Coding | Diastolic Blood Pressure Slice: Unordered, Open by value:code, value:system | ||||
coding:DBPCode | Σ | 1..1 | Coding | Diastolic Blood Pressure | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
system | Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | ||||
version | Σ | 0..1 | string | Version of the system - if relevant | ||||
code | Σ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 8462-4 | ||||
display | Σ | 0..1 | string | Representation defined by the system | ||||
userSelected | Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
text | Σ | 0..1 | string | Plain text representation of the concept | ||||
value[x] | SΣC | 0..1 | Quantity | Vital Sign Value recorded with UCUM Slice: Unordered, Open by type:$this Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. | ||||
value[x]:All Slices | Content/Rules for all slices | |||||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
value | SΣ | 1..1 | decimal | Numerical value (with implicit precision) | ||||
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. | ||||
unit | SΣ | 1..1 | string | Unit representation | ||||
system | SΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org | ||||
code | SΣ | 1..1 | code | Coded responses from the common UCUM units for vital signs value set. Fixed Value: mm[Hg] | ||||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
component:MeanBP | SΣC | 0..1 | BackboneElement | Mean blood pressure | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: VitalSigns (extensible): This identifies the vital sign result type. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
Slices for coding | Σ | 1..* | Coding | Code defined by a terminology system Slice: Unordered, Open by value:code, value:system | ||||
coding:MBPCode | Σ | 1..1 | Coding | Code defined by a terminology system | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
system | Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | ||||
version | Σ | 0..1 | string | Version of the system - if relevant | ||||
code | Σ | 1..1 | code | Mean blood pressure Fixed Value: 8478-0 | ||||
display | Σ | 0..1 | string | Representation defined by the system | ||||
userSelected | Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
text | Σ | 0..1 | string | Plain text representation of the concept | ||||
value[x] | SΣC | 0..1 | Vital Sign Value recorded with UCUM Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. | |||||
valueQuantity | Quantity | |||||||
valueCodeableConcept | CodeableConcept | |||||||
valueString | string | |||||||
valueBoolean | boolean | |||||||
valueInteger | integer | |||||||
valueRange | Range | |||||||
valueRatio | Ratio | |||||||
valueSampledData | SampledData | |||||||
valueTime | time | |||||||
valueDateTime | dateTime | |||||||
valuePeriod | Period | |||||||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
Documentation for this format |
Path | Conformance | ValueSet | URI | |||
Observation.meta.security | extensible | All Security Labelshttp://hl7.org/fhir/ValueSet/security-labels from the FHIR Standard | ||||
Observation.meta.tag | example | CommonTagshttp://hl7.org/fhir/ValueSet/common-tags from the FHIR Standard | ||||
Observation.language | preferred | CommonLanguages
http://hl7.org/fhir/ValueSet/languages from the FHIR Standard | ||||
Observation.status | required | ObservationStatushttp://hl7.org/fhir/ValueSet/observation-status|4.0.1 from the FHIR Standard | ||||
Observation.category | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | ||||
Observation.category:VSCat | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | ||||
Observation.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresult from the FHIR Standard | ||||
Observation.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard | ||||
Observation.bodySite | example | http://hl7.org/fhir/hspc/ValueSet/bpMeasBodyLocationPrecoordVShttp://hl7.org/fhir/hspc/ValueSet/bpMeasBodyLocationPrecoordVS | ||||
Observation.method | example | https://hl7.fr/ig/fhir/core/ValueSet/fr-core-vs-bp-measurement-methodhttps://hl7.fr/ig/fhir/core/ValueSet/fr-core-vs-bp-measurement-method | ||||
Observation.referenceRange.type | preferred | ObservationReferenceRangeMeaningCodeshttp://hl7.org/fhir/ValueSet/referencerange-meaning from the FHIR Standard | ||||
Observation.referenceRange.appliesTo | example | ObservationReferenceRangeAppliesToCodeshttp://hl7.org/fhir/ValueSet/referencerange-appliesto from the FHIR Standard | ||||
Observation.component.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresult from the FHIR Standard | ||||
Observation.component.value[x] | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1 from the FHIR Standard | ||||
Observation.component.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.component.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard | ||||
Observation.component:SystolicBP.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresult from the FHIR Standard | ||||
Observation.component:SystolicBP.value[x] | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1 from the FHIR Standard | ||||
Observation.component:SystolicBP.value[x].comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1 from the FHIR Standard | ||||
Observation.component:SystolicBP.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.component:SystolicBP.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard | ||||
Observation.component:DiastolicBP.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresult from the FHIR Standard | ||||
Observation.component:DiastolicBP.value[x] | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1 from the FHIR Standard | ||||
Observation.component:DiastolicBP.value[x].comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1 from the FHIR Standard | ||||
Observation.component:DiastolicBP.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.component:DiastolicBP.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard | ||||
Observation.component:MeanBP.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresult from the FHIR Standard | ||||
Observation.component:MeanBP.value[x] | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1 from the FHIR Standard | ||||
Observation.component:MeanBP.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.component:MeanBP.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | Observation | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | Observation | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | Observation | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() | |
obs-3 | error | Observation.referenceRange | Must have at least a low or a high or text : low.exists() or high.exists() or text.exists() | |
obs-6 | error | Observation | dataAbsentReason SHALL only be present if Observation.value[x] is not present : dataAbsentReason.empty() or value.empty() | |
obs-7 | error | Observation | If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present : value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty() | |
vs-1 | error | Observation.effective[x] | if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day : $this is dateTime implies $this.toString().length() >= 10 | |
vs-2 | error | Observation | If there is no component or hasMember element then either a value[x] or a data absent reason must be present. : (component.empty() and hasMember.empty()) implies (dataAbsentReason.exists() or value.exists()) | |
vs-3 | error | Observation.component, Observation.component:SystolicBP, Observation.component:DiastolicBP, Observation.component:MeanBP | If there is no a value a data absent reason must be present : value.exists() or dataAbsentReason.exists() |
This structure is derived from observation-bp
Summary
Mandatory: 3 elements (4 nested mandatory elements)
Fixed Value: 2 elements
Prohibited: 1 element
Structures
This structure refers to these other structures:
Extensions
This structure refers to these extensions:
Slices
This structure defines the following Slices:
Differential View
This structure is derived from observation-bp
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | 0..* | observation-bp | FHIR Blood Pressure Profile | |
meta | ||||
Slices for profile | 0..* | canonical(StructureDefinition) | Profiles this resource claims to conform to Slice: Unordered, Open by value:$this | |
profile:fr-canonical | 0..1 | canonical(StructureDefinition) | Profiles this resource claims to conform to Required Pattern: https://hl7.fr/ig/fhir/core/StructureDefinition/fr-core-observation-bp | |
Slices for extension | 0..* | Extension | Extension Slice: Unordered, Open by value:url | |
supportingInfo | 0..1 | Reference(Resource) | Other information that may be relevant to this event. URL: http://hl7.org/fhir/StructureDefinition/workflow-supportingInfo | |
code | ||||
coding | 1..* | Coding | Code defined by a terminology system | |
encounter | 0..1 | Reference(FR Core Encounter Profile) | Healthcare event during which this observation is made | |
effective[x] | 1..1 | dateTime, Period | Often just a dateTime for Vital Signs | |
performer | 0..* | Reference(CareTeam | FR Core Patient Profile | FR Core Practitioner Profile | PractitionerRole | FR Core Organization Profile | FR Core Related Person Profile) | Who is responsible for the observation | |
value[x] | 0..0 | |||
bodySite | 0..1 | CodeableConcept | Observed body part Binding: http://hl7.org/fhir/hspc/ValueSet/bpMeasBodyLocationPrecoordVS (example) | |
method | 0..1 | CodeableConcept | How it was done Binding: https://hl7.fr/ig/fhir/core/ValueSet/fr-core-vs-bp-measurement-method (example) | |
component:SystolicBP | 1..1 | BackboneElement | Used when reporting systolic and diastolic blood pressure. | |
code | ||||
coding | 1..* | Coding | Systolic Blood Pressure | |
value[x] | 0..1 | Quantity | Vital Sign Value recorded with UCUM Slice: Unordered, Open by | |
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |
component:DiastolicBP | 1..1 | BackboneElement | Used when reporting diastolic blood pressure. | |
code | ||||
coding | 1..* | Coding | Diastolic Blood Pressure | |
value[x] | 0..1 | Quantity | Vital Sign Value recorded with UCUM Slice: Unordered, Open by | |
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |
component:MeanBP | 0..1 | BackboneElement | Mean blood pressure | |
code | ||||
Slices for coding | 1..* | Coding | Code defined by a terminology system Slice: Unordered, Open by value:code, value:system | |
coding:MBPCode | 1..1 | Coding | Code defined by a terminology system | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Mean blood pressure Fixed Value: 8478-0 | |
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |
Documentation for this format |
Path | Conformance | ValueSet | URI |
Observation.bodySite | example | http://hl7.org/fhir/hspc/ValueSet/bpMeasBodyLocationPrecoordVShttp://hl7.org/fhir/hspc/ValueSet/bpMeasBodyLocationPrecoordVS | |
Observation.method | example | https://hl7.fr/ig/fhir/core/ValueSet/fr-core-vs-bp-measurement-methodhttps://hl7.fr/ig/fhir/core/ValueSet/fr-core-vs-bp-measurement-method |
Key Elements View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | C | 0..* | observation-bp | FHIR Blood Pressure Profile |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
Slices for extension | 0..* | Extension | Extension Slice: Unordered, Open by value:url | |
supportingInfo | 0..1 | Reference(Resource) | Other information that may be relevant to this event. URL: http://hl7.org/fhir/StructureDefinition/workflow-supportingInfo | |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
status | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: ObservationStatus (required) |
Slices for category | S | 1..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by value:coding.code, value:coding.system Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. |
category:VSCat | S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. |
coding | SΣ | 1..* | Coding | Code defined by a terminology system |
system | SΣ | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category |
code | SΣ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: vital-signs |
code | SΣ | 1..1 | CodeableConcept | Blood Pressure Binding: VitalSigns (extensible): This identifies the vital sign result type. |
Slices for coding | Σ | 1..* | Coding | Code defined by a terminology system Slice: Unordered, Open by value:code, value:system |
coding:BPCode | Σ | 1..1 | Coding | Code defined by a terminology system |
system | Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org |
code | Σ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 85354-9 |
subject | SΣ | 1..1 | Reference(Patient) | Who and/or what the observation is about |
encounter | Σ | 0..1 | Reference(FR Core Encounter Profile) | Healthcare event during which this observation is made |
effective[x] | SΣC | 1..1 | Often just a dateTime for Vital Signs | |
effectiveDateTime | dateTime | |||
effectivePeriod | Period | |||
performer | Σ | 0..* | Reference(CareTeam | FR Core Patient Profile | FR Core Practitioner Profile | PractitionerRole | FR Core Organization Profile | FR Core Related Person Profile) | Who is responsible for the observation |
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
bodySite | 0..1 | CodeableConcept | Observed body part Binding: http://hl7.org/fhir/hspc/ValueSet/bpMeasBodyLocationPrecoordVS (example) | |
method | 0..1 | CodeableConcept | How it was done Binding: https://hl7.fr/ig/fhir/core/ValueSet/fr-core-vs-bp-measurement-method (example) | |
Slices for component | SΣC | 2..* | BackboneElement | Used when reporting systolic and diastolic blood pressure. Slice: Unordered, Open by value:code.coding.code, value:code.coding.system |
component:All Slices | Content/Rules for all slices | |||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: VitalSigns (extensible): This identifies the vital sign result type. |
value[x] | SΣC | 0..1 | Vital Sign Value recorded with UCUM Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. | |
valueQuantity | Quantity | |||
valueCodeableConcept | CodeableConcept | |||
valueString | string | |||
valueBoolean | boolean | |||
valueInteger | integer | |||
valueRange | Range | |||
valueRatio | Ratio | |||
valueSampledData | SampledData | |||
valueTime | time | |||
valueDateTime | dateTime | |||
valuePeriod | Period | |||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
component:SystolicBP | SΣC | 1..1 | BackboneElement | Used when reporting systolic and diastolic blood pressure. |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: VitalSigns (extensible): This identifies the vital sign result type. |
Slices for coding | Σ | 1..* | Coding | Systolic Blood Pressure Slice: Unordered, Open by value:code, value:system |
coding:SBPCode | Σ | 1..1 | Coding | Systolic Blood Pressure |
system | Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org |
code | Σ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 8480-6 |
value[x] | SΣC | 0..1 | Quantity | Vital Sign Value recorded with UCUM Slice: Unordered, Open by type:$this Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. |
value[x]:All Slices | Content/Rules for all slices | |||
value | SΣ | 1..1 | decimal | Numerical value (with implicit precision) |
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. |
unit | SΣ | 1..1 | string | Unit representation |
system | SΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
code | SΣ | 1..1 | code | Coded responses from the common UCUM units for vital signs value set. Fixed Value: mm[Hg] |
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |
component:DiastolicBP | SΣC | 1..1 | BackboneElement | Used when reporting diastolic blood pressure. |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: VitalSigns (extensible): This identifies the vital sign result type. |
Slices for coding | Σ | 1..* | Coding | Diastolic Blood Pressure Slice: Unordered, Open by value:code, value:system |
coding:DBPCode | Σ | 1..1 | Coding | Diastolic Blood Pressure |
system | Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org |
code | Σ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 8462-4 |
value[x] | SΣC | 0..1 | Quantity | Vital Sign Value recorded with UCUM Slice: Unordered, Open by type:$this Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. |
value[x]:All Slices | Content/Rules for all slices | |||
value | SΣ | 1..1 | decimal | Numerical value (with implicit precision) |
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. |
unit | SΣ | 1..1 | string | Unit representation |
system | SΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
code | SΣ | 1..1 | code | Coded responses from the common UCUM units for vital signs value set. Fixed Value: mm[Hg] |
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |
component:MeanBP | SΣC | 0..1 | BackboneElement | Mean blood pressure |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: VitalSigns (extensible): This identifies the vital sign result type. |
Slices for coding | Σ | 1..* | Coding | Code defined by a terminology system Slice: Unordered, Open by value:code, value:system |
coding:MBPCode | Σ | 1..1 | Coding | Code defined by a terminology system |
system | Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org |
code | Σ | 1..1 | code | Mean blood pressure Fixed Value: 8478-0 |
value[x] | SΣC | 0..1 | Vital Sign Value recorded with UCUM Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. | |
valueQuantity | Quantity | |||
valueCodeableConcept | CodeableConcept | |||
valueString | string | |||
valueBoolean | boolean | |||
valueInteger | integer | |||
valueRange | Range | |||
valueRatio | Ratio | |||
valueSampledData | SampledData | |||
valueTime | time | |||
valueDateTime | dateTime | |||
valuePeriod | Period | |||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |
Documentation for this format |
Path | Conformance | ValueSet | URI |
Observation.status | required | ObservationStatushttp://hl7.org/fhir/ValueSet/observation-status|4.0.1 from the FHIR Standard | |
Observation.category | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | |
Observation.category:VSCat | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | |
Observation.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresult from the FHIR Standard | |
Observation.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
Observation.bodySite | example | http://hl7.org/fhir/hspc/ValueSet/bpMeasBodyLocationPrecoordVShttp://hl7.org/fhir/hspc/ValueSet/bpMeasBodyLocationPrecoordVS | |
Observation.method | example | https://hl7.fr/ig/fhir/core/ValueSet/fr-core-vs-bp-measurement-methodhttps://hl7.fr/ig/fhir/core/ValueSet/fr-core-vs-bp-measurement-method | |
Observation.component.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresult from the FHIR Standard | |
Observation.component.value[x] | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1 from the FHIR Standard | |
Observation.component.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
Observation.component:SystolicBP.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresult from the FHIR Standard | |
Observation.component:SystolicBP.value[x] | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1 from the FHIR Standard | |
Observation.component:SystolicBP.value[x].comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1 from the FHIR Standard | |
Observation.component:SystolicBP.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
Observation.component:DiastolicBP.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresult from the FHIR Standard | |
Observation.component:DiastolicBP.value[x] | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1 from the FHIR Standard | |
Observation.component:DiastolicBP.value[x].comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1 from the FHIR Standard | |
Observation.component:DiastolicBP.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
Observation.component:MeanBP.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresult from the FHIR Standard | |
Observation.component:MeanBP.value[x] | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1 from the FHIR Standard | |
Observation.component:MeanBP.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | Observation | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | Observation | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | Observation | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() | |
obs-6 | error | Observation | dataAbsentReason SHALL only be present if Observation.value[x] is not present : dataAbsentReason.empty() or value.empty() | |
obs-7 | error | Observation | If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present : value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty() | |
vs-1 | error | Observation.effective[x] | if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day : $this is dateTime implies $this.toString().length() >= 10 | |
vs-2 | error | Observation | If there is no component or hasMember element then either a value[x] or a data absent reason must be present. : (component.empty() and hasMember.empty()) implies (dataAbsentReason.exists() or value.exists()) | |
vs-3 | error | Observation.component, Observation.component:SystolicBP, Observation.component:DiastolicBP, Observation.component:MeanBP | If there is no a value a data absent reason must be present : value.exists() or dataAbsentReason.exists() |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
Observation | C | 0..* | observation-bp | FHIR Blood Pressure Profile | ||||
id | Σ | 0..1 | id | Logical id of this artifact | ||||
meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
versionId | Σ | 0..1 | id | Version specific identifier | ||||
lastUpdated | Σ | 0..1 | instant | When the resource version last changed | ||||
source | Σ | 0..1 | uri | Identifies where the resource comes from | ||||
Slices for profile | Σ | 0..* | canonical(StructureDefinition) | Profiles this resource claims to conform to Slice: Unordered, Open by value:$this | ||||
profile:fr-canonical | Σ | 0..1 | canonical(StructureDefinition) | Profiles this resource claims to conform to Required Pattern: https://hl7.fr/ig/fhir/core/StructureDefinition/fr-core-observation-bp | ||||
security | Σ | 0..* | Coding | Security Labels applied to this resource Binding: All Security Labels (extensible): Security Labels from the Healthcare Privacy and Security Classification System. | ||||
tag | Σ | 0..* | Coding | Tags applied to this resource Binding: CommonTags (example): Codes that represent various types of tags, commonly workflow-related; e.g. "Needs review by Dr. Jones". | ||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
contained | 0..* | Resource | Contained, inline Resources | |||||
Slices for extension | 0..* | Extension | Extension Slice: Unordered, Open by value:url | |||||
supportingInfo | 0..1 | Reference(Resource) | Other information that may be relevant to this event. URL: http://hl7.org/fhir/StructureDefinition/workflow-supportingInfo | |||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
identifier | Σ | 0..* | Identifier | Business Identifier for observation | ||||
basedOn | Σ | 0..* | Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) | Fulfills plan, proposal or order | ||||
partOf | Σ | 0..* | Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) | Part of referenced event | ||||
status | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: ObservationStatus (required) | ||||
Slices for category | S | 1..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by value:coding.code, value:coding.system Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. | ||||
category:VSCat | S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
coding | SΣ | 1..* | Coding | Code defined by a terminology system | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
system | SΣ | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | ||||
version | Σ | 0..1 | string | Version of the system - if relevant | ||||
code | SΣ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: vital-signs | ||||
display | Σ | 0..1 | string | Representation defined by the system | ||||
userSelected | Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
text | Σ | 0..1 | string | Plain text representation of the concept | ||||
code | SΣ | 1..1 | CodeableConcept | Blood Pressure Binding: VitalSigns (extensible): This identifies the vital sign result type. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
Slices for coding | Σ | 1..* | Coding | Code defined by a terminology system Slice: Unordered, Open by value:code, value:system | ||||
coding:BPCode | Σ | 1..1 | Coding | Code defined by a terminology system | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
system | Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | ||||
version | Σ | 0..1 | string | Version of the system - if relevant | ||||
code | Σ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 85354-9 | ||||
display | Σ | 0..1 | string | Representation defined by the system | ||||
userSelected | Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
text | Σ | 0..1 | string | Plain text representation of the concept | ||||
subject | SΣ | 1..1 | Reference(Patient) | Who and/or what the observation is about | ||||
focus | Σ | 0..* | Reference(Resource) | What the observation is about, when it is not about the subject of record | ||||
encounter | Σ | 0..1 | Reference(FR Core Encounter Profile) | Healthcare event during which this observation is made | ||||
effective[x] | SΣC | 1..1 | Often just a dateTime for Vital Signs | |||||
effectiveDateTime | dateTime | |||||||
effectivePeriod | Period | |||||||
issued | Σ | 0..1 | instant | Date/Time this version was made available | ||||
performer | Σ | 0..* | Reference(CareTeam | FR Core Patient Profile | FR Core Practitioner Profile | PractitionerRole | FR Core Organization Profile | FR Core Related Person Profile) | Who is responsible for the observation | ||||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
note | 0..* | Annotation | Comments about the observation | |||||
bodySite | 0..1 | CodeableConcept | Observed body part Binding: http://hl7.org/fhir/hspc/ValueSet/bpMeasBodyLocationPrecoordVS (example) | |||||
method | 0..1 | CodeableConcept | How it was done Binding: https://hl7.fr/ig/fhir/core/ValueSet/fr-core-vs-bp-measurement-method (example) | |||||
specimen | 0..1 | Reference(Specimen) | Specimen used for this observation | |||||
device | 0..1 | Reference(Device | DeviceMetric) | (Measurement) Device | |||||
referenceRange | C | 0..* | BackboneElement | Provides guide for interpretation | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
low | C | 0..1 | SimpleQuantity | Low Range, if relevant | ||||
high | C | 0..1 | SimpleQuantity | High Range, if relevant | ||||
type | 0..1 | CodeableConcept | Reference range qualifier Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range. | |||||
appliesTo | 0..* | CodeableConcept | Reference range population Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to. | |||||
age | 0..1 | Range | Applicable age range, if relevant | |||||
text | 0..1 | string | Text based reference range in an observation | |||||
hasMember | Σ | 0..* | Reference(QuestionnaireResponse | MolecularSequence | Vital Signs Profile) | Used when reporting vital signs panel components | ||||
derivedFrom | Σ | 0..* | Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | MolecularSequence | Vital Signs Profile) | Related measurements the observation is made from | ||||
Slices for component | SΣC | 2..* | BackboneElement | Used when reporting systolic and diastolic blood pressure. Slice: Unordered, Open by value:code.coding.code, value:code.coding.system | ||||
component:All Slices | Content/Rules for all slices | |||||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: VitalSigns (extensible): This identifies the vital sign result type. | ||||
value[x] | SΣC | 0..1 | Vital Sign Value recorded with UCUM Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. | |||||
valueQuantity | Quantity | |||||||
valueCodeableConcept | CodeableConcept | |||||||
valueString | string | |||||||
valueBoolean | boolean | |||||||
valueInteger | integer | |||||||
valueRange | Range | |||||||
valueRatio | Ratio | |||||||
valueSampledData | SampledData | |||||||
valueTime | time | |||||||
valueDateTime | dateTime | |||||||
valuePeriod | Period | |||||||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
component:SystolicBP | SΣC | 1..1 | BackboneElement | Used when reporting systolic and diastolic blood pressure. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: VitalSigns (extensible): This identifies the vital sign result type. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
Slices for coding | Σ | 1..* | Coding | Systolic Blood Pressure Slice: Unordered, Open by value:code, value:system | ||||
coding:SBPCode | Σ | 1..1 | Coding | Systolic Blood Pressure | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
system | Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | ||||
version | Σ | 0..1 | string | Version of the system - if relevant | ||||
code | Σ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 8480-6 | ||||
display | Σ | 0..1 | string | Representation defined by the system | ||||
userSelected | Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
text | Σ | 0..1 | string | Plain text representation of the concept | ||||
value[x] | SΣC | 0..1 | Quantity | Vital Sign Value recorded with UCUM Slice: Unordered, Open by type:$this Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. | ||||
value[x]:All Slices | Content/Rules for all slices | |||||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
value | SΣ | 1..1 | decimal | Numerical value (with implicit precision) | ||||
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. | ||||
unit | SΣ | 1..1 | string | Unit representation | ||||
system | SΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org | ||||
code | SΣ | 1..1 | code | Coded responses from the common UCUM units for vital signs value set. Fixed Value: mm[Hg] | ||||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
component:DiastolicBP | SΣC | 1..1 | BackboneElement | Used when reporting diastolic blood pressure. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: VitalSigns (extensible): This identifies the vital sign result type. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
Slices for coding | Σ | 1..* | Coding | Diastolic Blood Pressure Slice: Unordered, Open by value:code, value:system | ||||
coding:DBPCode | Σ | 1..1 | Coding | Diastolic Blood Pressure | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
system | Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | ||||
version | Σ | 0..1 | string | Version of the system - if relevant | ||||
code | Σ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 8462-4 | ||||
display | Σ | 0..1 | string | Representation defined by the system | ||||
userSelected | Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
text | Σ | 0..1 | string | Plain text representation of the concept | ||||
value[x] | SΣC | 0..1 | Quantity | Vital Sign Value recorded with UCUM Slice: Unordered, Open by type:$this Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. | ||||
value[x]:All Slices | Content/Rules for all slices | |||||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
value | SΣ | 1..1 | decimal | Numerical value (with implicit precision) | ||||
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. | ||||
unit | SΣ | 1..1 | string | Unit representation | ||||
system | SΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org | ||||
code | SΣ | 1..1 | code | Coded responses from the common UCUM units for vital signs value set. Fixed Value: mm[Hg] | ||||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
component:MeanBP | SΣC | 0..1 | BackboneElement | Mean blood pressure | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: VitalSigns (extensible): This identifies the vital sign result type. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
Slices for coding | Σ | 1..* | Coding | Code defined by a terminology system Slice: Unordered, Open by value:code, value:system | ||||
coding:MBPCode | Σ | 1..1 | Coding | Code defined by a terminology system | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
system | Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | ||||
version | Σ | 0..1 | string | Version of the system - if relevant | ||||
code | Σ | 1..1 | code | Mean blood pressure Fixed Value: 8478-0 | ||||
display | Σ | 0..1 | string | Representation defined by the system | ||||
userSelected | Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
text | Σ | 0..1 | string | Plain text representation of the concept | ||||
value[x] | SΣC | 0..1 | Vital Sign Value recorded with UCUM Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. | |||||
valueQuantity | Quantity | |||||||
valueCodeableConcept | CodeableConcept | |||||||
valueString | string | |||||||
valueBoolean | boolean | |||||||
valueInteger | integer | |||||||
valueRange | Range | |||||||
valueRatio | Ratio | |||||||
valueSampledData | SampledData | |||||||
valueTime | time | |||||||
valueDateTime | dateTime | |||||||
valuePeriod | Period | |||||||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
Documentation for this format |
Path | Conformance | ValueSet | URI | |||
Observation.meta.security | extensible | All Security Labelshttp://hl7.org/fhir/ValueSet/security-labels from the FHIR Standard | ||||
Observation.meta.tag | example | CommonTagshttp://hl7.org/fhir/ValueSet/common-tags from the FHIR Standard | ||||
Observation.language | preferred | CommonLanguages
http://hl7.org/fhir/ValueSet/languages from the FHIR Standard | ||||
Observation.status | required | ObservationStatushttp://hl7.org/fhir/ValueSet/observation-status|4.0.1 from the FHIR Standard | ||||
Observation.category | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | ||||
Observation.category:VSCat | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | ||||
Observation.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresult from the FHIR Standard | ||||
Observation.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard | ||||
Observation.bodySite | example | http://hl7.org/fhir/hspc/ValueSet/bpMeasBodyLocationPrecoordVShttp://hl7.org/fhir/hspc/ValueSet/bpMeasBodyLocationPrecoordVS | ||||
Observation.method | example | https://hl7.fr/ig/fhir/core/ValueSet/fr-core-vs-bp-measurement-methodhttps://hl7.fr/ig/fhir/core/ValueSet/fr-core-vs-bp-measurement-method | ||||
Observation.referenceRange.type | preferred | ObservationReferenceRangeMeaningCodeshttp://hl7.org/fhir/ValueSet/referencerange-meaning from the FHIR Standard | ||||
Observation.referenceRange.appliesTo | example | ObservationReferenceRangeAppliesToCodeshttp://hl7.org/fhir/ValueSet/referencerange-appliesto from the FHIR Standard | ||||
Observation.component.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresult from the FHIR Standard | ||||
Observation.component.value[x] | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1 from the FHIR Standard | ||||
Observation.component.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.component.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard | ||||
Observation.component:SystolicBP.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresult from the FHIR Standard | ||||
Observation.component:SystolicBP.value[x] | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1 from the FHIR Standard | ||||
Observation.component:SystolicBP.value[x].comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1 from the FHIR Standard | ||||
Observation.component:SystolicBP.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.component:SystolicBP.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard | ||||
Observation.component:DiastolicBP.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresult from the FHIR Standard | ||||
Observation.component:DiastolicBP.value[x] | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1 from the FHIR Standard | ||||
Observation.component:DiastolicBP.value[x].comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1 from the FHIR Standard | ||||
Observation.component:DiastolicBP.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.component:DiastolicBP.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard | ||||
Observation.component:MeanBP.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresult from the FHIR Standard | ||||
Observation.component:MeanBP.value[x] | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1 from the FHIR Standard | ||||
Observation.component:MeanBP.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.component:MeanBP.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | Observation | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | Observation | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | Observation | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() | |
obs-3 | error | Observation.referenceRange | Must have at least a low or a high or text : low.exists() or high.exists() or text.exists() | |
obs-6 | error | Observation | dataAbsentReason SHALL only be present if Observation.value[x] is not present : dataAbsentReason.empty() or value.empty() | |
obs-7 | error | Observation | If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present : value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty() | |
vs-1 | error | Observation.effective[x] | if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day : $this is dateTime implies $this.toString().length() >= 10 | |
vs-2 | error | Observation | If there is no component or hasMember element then either a value[x] or a data absent reason must be present. : (component.empty() and hasMember.empty()) implies (dataAbsentReason.exists() or value.exists()) | |
vs-3 | error | Observation.component, Observation.component:SystolicBP, Observation.component:DiastolicBP, Observation.component:MeanBP | If there is no a value a data absent reason must be present : value.exists() or dataAbsentReason.exists() |
This structure is derived from observation-bp
Summary
Mandatory: 3 elements (4 nested mandatory elements)
Fixed Value: 2 elements
Prohibited: 1 element
Structures
This structure refers to these other structures:
Extensions
This structure refers to these extensions:
Slices
This structure defines the following Slices:
Other representations of profile: CSV, Excel, Schematron